The figure above shows a typical interconnection of the Event, Action and Condition
blocks. It holds true in general that an action is always tied with a selected event and is
executed when a selected condition is met. The condition is optional and if none is
selected, the action is executed whenever the assigned event occurs. 2N Helios IP
®
defines a number of events, actions and conditions to be further set.Automation
Refer to the subsections below for the full list.
The example shown in the figure above can be interpreted as follows: The SetOutput
action (digital output setting) is executed if the event (logic input1InputChanged
change from log.0 to log. 1) arises and the (active profile 1) condition is met.Profile
The web interface helps you configure block combinations2N Helios IP
®
(Automation) easily. The configuration shown in the figure below corresponds to the
example above.