Shrnutí obsahu

Strany 1 - User Manual

2N® BRI Lite/Enterprise BRI-VoIP-GSM/UMTS Gateway User Manual Version 1.1 Firmware 1.5.0 www.2n.cz

Strany 2

Product Description 1.1 10 DialThru (2N® BRI Enterprise) The difference between 2N® BRI Enterprise and 2N® BRI Lite lies in the DialThru

Strany 4

101 9 8. Supplementary Information This section provides supplementary information on the 2N® BRI Enterprise / BRI Lite product. Here is what

Strany 5

Directives, Laws and Regulations 8.1 102 8.1 Directives, Laws and Regulations 2N BRI Enterprise/Lite conforms to the following directives and regu

Strany 6

Troubleshooting 8.2 103 8.2 Troubleshooting For the most frequently asked questions refer to FAQ.2n.cz.  No LED is shining on 2N® BRI Enterpris

Strany 7 - Overview

Troubleshooting 8.2 104  Call is not disconnected immediately  Call release in GSM network can take up to 2s. If you are experimenting longer del

Strany 8 - 1.1 Product Description

List of Abbreviations 8.3 105 8.3 List of Abbreviations  API (Application Programming Interface)  ASR (Answer Seizure Ratio)  BIOS (Basic I

Strany 9

List of Abbreviations 8.3 106  LED (Light Emited Diod) Electric light-emitting semi-conductor component.  NT (Network Termination) Network termi

Strany 10 - Product Description

General Instructions and Cautions 8.4 107 8.4 General Instructions and Cautions Please read this User Manual carefully before using the product. Fo

Strany 11

General Instructions and Cautions 8.4 108 Electric Waste and Used Battery Pack Handling Do not place used electric devices and battery packs into

Strany 12 - 1.2 Safety Precautions

2N TELEKOMUNIKACE a.s. Mod Tel.: +420 261 301 500, Fax: +420 261 301 599 E-mail: [email protected] Web: www

Strany 13 - 1.3 Upgrade

Product Description 1.1 11 The 2N® BRI Lite GSM gateway contains just one ISDN BRI port and thus cannot work in the DialThru mode. It c

Strany 14 - 1.4 Terms and Symbols Used

Safety Precautions 1.2 12 1.2 Safety Precautions It is prohibited to use any transmitters, including the GSM/UMTS gateways, in areas where ex

Strany 15 - Installation

Upgrade 1.3 13 1.3 Upgrade The manufacturer reserves the right to modify the product in order to improve its qualities. 

Strany 16 - SIP Components

Terms and Symbols Used 1.4 14 1.4 Terms and Symbols Used Manual Symbols Safety  Always abide by this information to prevent persons from injury

Strany 17 - SIP Signalling Messages

15 2 2. Description and Installation This section describes the 2N® BRI Enterprise / 2N® BRI Lite product and its installation. Here is what y

Strany 18 - 2.1 Before You Start

16 For 2N BRI gateway, quadruple the above mentioned rates (two fully duplex calls) and add the TCP and IP header transmission rate to the result to

Strany 19 - Before You Start

17  Location server  receives registration requests from the UA and updates the terminal database accordingly. All the server components (Proxy, R

Strany 20

Before You Start 2.1 18 2.1 Before You Start Caution  Make sure that you are equipped with all system components necessary for putting

Strany 21

Before You Start 2.1 19 Connector Lay-Out – Lower Side The following connectors are available on the BRI gateway bottom: Connector type BRI Lite BRI

Strany 22 - Potential GSM/UMTS Troubles

The 2N TELEKOMUNIKACE a.s. joint-stock company is a Czech manufacturer and supplier of telecommunications equipment. The product family develope

Strany 23 - Installation Conditions

Before You Start 2.1 20 Connector Lay-Out – Upper Side There are SMA female antenna connectors to each GSM/UMTS module on the 2N BRI Enterprise / L

Strany 24 - SIM Card Inserting/Removing

Before You Start 2.1 21 Status LED Indicators – 2N® BRI Enterprise The 2N BRI Enterprise status is indicated by five LEDs on the front side. BR

Strany 25 - Antenna Connection

Before You Start 2.1 22 Potential GSM/UMTS Troubles All 2N GSM gateways work reliably under a long-time full load. The following problems may be cau

Strany 26 - Brief Installation Guide

Brief Installation Guide 2.2 23 2.2 Brief Installation Guide Installation Conditions The following installation conditions have to be met for a pro

Strany 27 - Power Supply Connection

Brief Installation Guide 2.2 24  2N BRI Enterprise / BRI Lite may never be exposed to direct sunshine or placed close to heat source

Strany 28 - Ethernet Cable Connection

Brief Installation Guide 2.2 25 Caution  Be sure to set such provider/SIM card services as call forwarding, call barring, preferred n

Strany 29

Brief Installation Guide 2.2 26

Strany 30 - NT and TE Connectors

Brief Installation Guide 2.2 27 Warning  Tighten the antenna connector gently with your hand  never use a wrench!  Being a source o

Strany 31

Brief Installation Guide 2.2 28 Warning  Connecting a defective or inappropriate power supply adapter may lead to a temporary or permanent 2N BRI

Strany 32 - Configurations

Brief Installation Guide 2.2 29 RJ-45 LAN Connector

Strany 33

Table of Contents 1. Product Overview... 7 1.1 Product Description ...

Strany 34 - 2.4 IP Voice Transmission

Brief Installation Guide 2.2 30 NT and TE Connectors ISDN devices are connected to the NT/TE connectors depending on the configuration of your tel

Strany 35

Brief Installation Guide 2.2 31 Caution  2N BRI Lite is equipped with just one ISDN BRI. Hence, two independent devices cannot be connected at t

Strany 36 - IP Voice Transmission

Available ISDN BRI Extension Configurations 2.3 32 2.3 Available ISDN BRI Extension Configurations You have to know the way of connection o

Strany 37 - BRI Enterprise Connection

Available ISDN BRI Extension Configurations 2.3 33 Point-to-Multipoint Configuration Point-to-Multipoint (EuroISDN with MSN) is another type o

Strany 38

IP Voice Transmission 2.4 34 2.4 IP Voice Transmission Speech Encoding Methods Voice transmission is strictly separated from signalling in VoIP net

Strany 39

IP Voice Transmission 2.4 35 The SIP and ITU-T H.323 recommended protocols are mostly used for connection establishing, maintaining and cancelling.

Strany 40

IP Voice Transmission 2.4 36 The answers to the SIP messages are numerically coded as the case is with the http protocol. Below are the most import

Strany 41 - BRI Gateway

Types of 2N® BRI Enterprise Connection 2.5 37 2.5 Types of 2N® BRI Enterprise Connection This subsection deals with the types of connection of the

Strany 42

Types of 2N® BRI Enterprise Connection 2.5 38 2N® BRI Enterprise Point-to-Point Connection This type of connection is especially suitable for direct

Strany 43 - 3.2 Call Routing Principles

Types of 2N® BRI Enterprise Connection 2.5 39 With multiple GSM gateways, the connection lay-out is as follows: 2N® BRI Enterprise Connection as

Strany 44 - LCR Table

Outgoing GSM Call Routing from Internal ISDN ... 44 Incoming GSM Call Routing ...

Strany 46 - DISA Message

41 3 3. Making Calls via BRI Gateway This section describes the call routing techniques via an ISDN BRI GSM gateway. The purpose of the settings

Strany 47 - First Launch

Supported 2N BRI Gateway Functions 3.1 42 3.1 Supported 2N BRI Gateway Functions  Time/destination based call routing  B-channel based call ro

Strany 48

Call Routing Principles 3.2 43 3.2 Call Routing Principles 2N® BRI Lite The gateway is equipped with one BRI ISDN and one VoIP-SIP ports. You can s

Strany 49 - 4.1 Ethernet Interface

Call Routing Principles 3.2 44 Tip  2NBRI Enterprise / BRI Lite can also route outgoing calls into the GSM/UMTS networks according to the B-chan

Strany 50 - MAC Address

Call Routing Principles 3.2 45  In case the prefix and call time comply with the routing rules, the call is routed according to t

Strany 51 - 4.2 Licence

Call Routing Principles 3.2 46 setup. Define the minimum and maximum counts of DTMF digits in the Incoming GSM calls menu.  If the ga

Strany 52 - 4.3 Firmware Version

47 4 4. First Launch Having completed the physical installation, get acquainted with the factory settings and operation of the 2N® BR

Strany 54

49 4.1 Ethernet Interface The BRI gateway can be fully configured via the web interface at http://IP_gateway_address. Make sure that a device equip

Strany 55

8.1 Directives, Laws and Regulations ... 102 8.2 Troubleshooting ...

Strany 56 - Interface

50 MAC Address The BRI gateway has a unique, factory-set MAC (Media Access Control) address. Refer to the rear side label of your device or the gate

Strany 57 - Essential Data

51 4.2 Licence The BRI gateway can contain different licence keys depending on the Part No. Refer to the Gateway control - Firmware/Licence secti

Strany 58 - Home Page

52 4.3 Firmware Version Upgrade your  / BRI Lite gateway with the latest firmware version available for this GSM gateway type bef

Strany 59 - Gateway

53 4.4 Factory Reset Should you forget your password or set the IP interface incorrectly, you can reset the factory values. Press the Reset button

Strany 60 - Gateway Control

54 4.5 Basic Configuration – Step by Step This subsection helps you put your BRI gateway in operation for the first time. Refer to the paragraphs o

Strany 61

55 Should you have problems with the gateway functions, follows the instructions below please: - Read the User Manual carefully and check all the p

Strany 62 - Gateway Configuration

56 5 5. Introduction to Configuration Interface This section introduces the configuration interface of the 2N® BRI Enterprise / BRI Lite pro

Strany 63 - Caution

57 5.1 Configuration Web Interface Essential Data The 2N BRI Enterprise / BRI Lite web interface supports the following web browsers: MS Internet

Strany 64 - VoIP parameters

58 A five-minute4 time limit is defined for login, which is renewed automatically when the user keeps active on the web interface. When this time int

Strany 65

59 configuration items. You can see the current login time counter status and the Refresh button for time limit refreshing in the right-hand upper co

Strany 67 - GSM basic parameters

60 Gateway Control Gateway control helps you:  Monitor the current state of each GSM gateway parts;  Check and set the GSM gateway licence;  Vi

Strany 68

61  Licence key for gateway  helps you insert a new GSM gateway connection licence. Caution  By inserting a new licence code you restart the GSM

Strany 69

62 Module status The window displays the current status of each GSM/UMTS channel. Refer to Subs. 6.4, page 91 for more details. Module control The w

Strany 70 - GSM outgoing groups

63 Summer / winter time  Automatically move to summer/winter time  enable automatic GSM gateway system time change for winter/summer time format t

Strany 71

64 List of emergency numbers The window displays a list of emergency numbers, which are normally routed to the BRI interface. If the BRI line is disc

Strany 72

65  First RTP port (even: 1024  65524)  set the number of the first RTP port. The RTP port number must be even according to the recommendation.

Strany 73

66 Tones generated to VoIP  Ring tone to VoIP  enable generation of a user ring tone or transfer of the real ring tone from the GSM/UMTS networks.

Strany 74 - GSM incoming groups

67  Receive dial number from Subaddress  use this parameter to receive dialling from the subaddress element instead of standard CDN.  

Strany 75 - Prefixes

68  Relax timeout [s]  set the timeout between the end of the last call and beginning of the next call made via one and the same GSM

Strany 76 - LCR table

69 o Lack of digits in OVERLAP mode  any call that fails to meet the minimum digits count requirement will be rejected. o Restricted number prefi

Strany 77

7 1 1. Product Overview In this section, we introduce the 2N® BRI Lite / Enterprise product, outline its application options and hi

Strany 78 - Configuration backup

70 63 Service or option unavailable 503 Service unavailable 65 Bearer cap, not implemented 501 Not implemented 79 Service or option not implemented 5

Strany 79 - Restart

71 Note  The INVITE message must contain the called and calling numbers in order that the SMS at no answer function may work properly.  Delay fo

Strany 80

72 o MCC  Mobile Country Code  national code (Czech Republic  230, e.g.) o MNC  Mobile Network Code  GSM network code (T-Mobile 01, O202, Voda

Strany 81 - Via Terminal

73  Next count  set the length of one pulse in seconds after the time defined in the First count parameter elapses. Note  Set the two parameters

Strany 82

74 GSM incoming groups 2N BRI gateway allows you to work with two groups of incoming calls. You can set different values for each of them. General se

Strany 83 - 6.2 GSM Gateway Behaviour

75 + +420261301500 Add + before CLIP 00 00420261301500 Add 00 before CLIP -- 0261301500 First two digits removed from CLIP ---99 99261301500 First th

Strany 84 - Configuration AT Commands

76 Basic settings  GSM network ID  set the prefix list user code for easier orientation in the LCR.  Default count of digits  default length o

Strany 85 - List of Terminal AT Commands

77 CLIP routing table + CallBack Use the table to set a fixed CLIP assignment of incoming CLIPs from GSM to the numbers of extensions to which incomi

Strany 86

78 Login configuration Use this window to set the access password and name for the 2N BRI gateway web interface. Use the same access data for Telnet

Strany 87

79 Documentation Download the User Manual saved in the gateway. Caution  The User Manual version will not change during the gateway firmw

Strany 88 - Tracing Commands

Product Description 1.1 8 1.1 Product Description The 2N Enterprise / BRI Lite GSM gateway provides direct interconnection of the ISDN with

Strany 90

81 7 6. Configuration Via Terminal Communication with the 2N® BRI Enterprise / BRI Lite gateway is via the LAN. This connection provides unifor

Strany 92

LAN Communication Setting 6.1 83 6.1 LAN Communication Setting First set the 2N BRI gateway IP address to communicate with the gateway via your LAN

Strany 93 - Status Messages

List of Terminal AT Commands 6.3 84 &V ...view active parameters (system) &VI ...view active parameters (isdn) &V0 ...view active parame

Strany 94 - 6.5 LOG Files

List of Terminal AT Commands 6.3 85 System Settings %S85=sms ...no answer sms text (max 63 chars) %S90=mode ...operating mode of GSM module alloc

Strany 95 - 6.6 Call Data Records (CDR)

List of Terminal AT Commands 6.3 86 c3=req.mod/grp not ready (TEMPFAIL=41) c4=pref grps not ready (CONGEST=42) %I06=sack,proc,prog,ale ...pr

Strany 96

List of Terminal AT Commands 6.3 87 - 1=EU (dial = constantly 425Hz, ring = 1000+4000msec 425Hz) - 2=CZ (dial = 300/300/600/1200msec 425Hz, ring =

Strany 97 - Parameters

List of Terminal AT Commands 6.3 88 %N#2=pref/dig,... ...pref. list extension (max 63 chars) %N#3=pref/dig,... ...pref. list extension (max 63 chars

Strany 98 - Statistics - Description

List of Terminal AT Commands 6.3 89 x=3  Layers TCP, Telnet x=4  Layer Telnet AT!Rx Start tracing of ISDN BRI & GSM on layer x x=1  Layers 1,

Strany 99 - Ethernet

Product Description 1.1 9 2N® BRI Enterprise / 2N® BRI Lite Basic Features  Integration of the best features of two communication technologies: I

Strany 100

0 90 *smsout: ch,ix,ref was sent and was not saved into SIM card: Ref SMS statu

Strany 101 - Information

Status Messages 6.4 91 6.4 Status Messages ISDN Layer 1 Message Status ID Name Description 0 DEACT Deactivation – no signal received 1 ACTIVE Acti

Strany 102

Status Messages 6.4 92 7 NWAIT Awaiting GSM log-in SETUP 8 IDLE Rest status, can start/receive call, execute AT&G command CALL/CMD 9 CALL Call r

Strany 103 - 8.2 Troubleshooting

Status Messages 6.4 93 Command Shell Statuses Command Row Message Status ID Name Description 0 IDLE Rest status, awaiting AT commands 1 REQUEST Co

Strany 104 - Troubleshooting

LOG Files 6.5 94 6.5 LOG Files Type Text Description POWER [Power on] System switched on [Power off] System switched off [Warm boot] Restart of s

Strany 105 - 8.3 List of Abbreviations

Call Data Records (CDR) 6.6 95 L: undef.frame Received unknown type packed M: (I field) Received wrong I-packet (numbered packet) N: frame size R

Strany 106 - List of Abbreviations

Statistics - Description 6.7 96 6.7 Statistics - Description [ Total statistics ] network (reset) minutes hhhh:mm:ss calls reject failed

Strany 107

97 8 7. Technical Parameters In this section, the technical parameters of the 2N® BRI Enterprise / BRI Lite product are described.

Strany 108

Statistics - Description 6.7 98 Wireless Mobile network type GSM 850/900/1800/1900MHz, UMTS/3G at 850/900/1800/2100MHZ  according to the module ty

Strany 109 - PR1877 v1.1

0 99 Ethernet Type Ethernet 10/100BaseT Connector RJ-45 Protocols Telnet, http, SIP VoIP signalling SIP (TCP, UDP), DTMF RFC2833 Voice codecs G.7