Parameters
Code – define the numeric code.
Valid values:
numeric code – 12345, e.g.
SuppressTones suppress sound signalling initiated by receiving of an invalid
numeric code. The parameter is optional.
Valid values:
0 – tones are not suppressed
1 – tones are suppressed (default value).
Variables
Code – the received numeric code which was the last to generate this event.
Example
Event generated by entering code 12345* on a keypad:
Event.CodeEntered: Code=12345
Event.CardEntered
The block defines the event generated by tapping (swiping) of the RFIDCardEntered
card with the defined ID (for RFID card reader models only).
Parameters
Card define the RFID card ID; refer to the Card Reader subsection in the 2N
®
.Helios IP Configuration Manual
Valid values:
valid – any valid card (included in the intercom card list)
invalid – any invalid card
any - any valid or invalid card
card ID - defined card ID e.g. 3F00F34F78.
SuppressTones suppress sound signalling initiated by detection of an invalid
card. The parameter is optional.
Valid values:
0 – tones are not suppressed
1 – tones are suppressed (default value).
Variables
Card – ID of the detected card which was the last to generate this event.